Allen Bradley Overload Heater Sizing
Automation is our foundation.
Allen bradley overload heater sizing. Find heater table number below using the product class controller size and phase. The old style type n heater elements are used with bulletin 709 motor starters and overload relay blocks. Type w heater elements for bulletin 509 starters table 150. Find heater table number below using the product class type of enclosure and control size.
A class 30 overload relay will trip in 30 seconds or less at a current equal to 600 percent of its rating. That overload relay you have is basically the same one that would go on a size 1 starter usually limited to 27a. The allen bradley heater tables below are two of the most common used for sizing standard overload relay protection for type n and type w heater elements. Because its not hitched to a starter its allowing you to go to 40a.
Control size motor amp phase enclosure 1. Sizing for overload is important to avoid serious damage for electrical application such as motor starter machinery or others electrical equipment. Allen bradley overload relay heater tables for bulletin 709 509. Refer to the specified table and use the controller size and motor amps to select the heater catalog number.
Our future is propelled by our long legacy of creating allen bradley integrated control and information solutions that make you as productive as possible. 0 18 0 20 0 22 0 24 0 26. According to nec the general requirement for overload sizing be set around 115 or 125 from full load ampere we should setting the overload relay within this parameter to avoid electric motor from serious damage. Refer to the specified table and use control size and motor amps to select the heater code number.
In this episode daryn sheds light on the importance of motor starter heater sizing how to do it properly and efficiently. If motor amps are not. Allen bradley heater tables. If motor amps are not.
Heater table number is found in the column under the type of overload and phase. While the type w heater elements are used with current bulletin 509 motor starters and overload relay. B controller size b motor amp b phase 1. We are dedicated innovators delivering smarter connected solutions to the world around us.
Allen bradley standard overload relay protection using either type n or w heater elements provide class 20 operation and are recommended for general application. This provides class 20. The next column to the right would be for a size 2 overload and so on. Heater table number is found in the column under the type of overload and phase.